| //===- LiveDebugValues.cpp - Tracking Debug Value MIs ---------------------===// | |
| // | |
| // The LLVM Compiler Infrastructure | |
| // | |
| // This file is distributed under the University of Illinois Open Source | |
| // License. See LICENSE.TXT for details. | |
| // | |
| //===----------------------------------------------------------------------===// | |
| /// | |
| /// This pass implements a data flow analysis that propagates debug location | |
| /// information by inserting additional DBG_VALUE instructions into the machine | |
| /// instruction stream. The pass internally builds debug location liveness | |
| /// ranges to determine the points where additional DBG_VALUEs need to be | |
| /// inserted. | |
| /// | |
| /// This is a separate pass from DbgValueHistoryCalculator to facilitate | |
| /// testing and improve modularity. | |
| /// | |
| //===----------------------------------------------------------------------===// | |
| #include "llvm/ADT/DenseMap.h" | |
| #include "llvm/ADT/PostOrderIterator.h" | |
| #include "llvm/ADT/SmallPtrSet.h" | |
| #include "llvm/ADT/SmallVector.h" | |
| #include "llvm/ADT/SparseBitVector.h" | |
| #include "llvm/ADT/Statistic.h" | |
| #include "llvm/ADT/UniqueVector.h" | |
| #include "llvm/CodeGen/LexicalScopes.h" | |
| #include "llvm/CodeGen/MachineBasicBlock.h" | |
| #include "llvm/CodeGen/MachineFrameInfo.h" | |
| #include "llvm/CodeGen/MachineFunction.h" | |
| #include "llvm/CodeGen/MachineFunctionPass.h" | |
| #include "llvm/CodeGen/MachineInstr.h" | |
| #include "llvm/CodeGen/MachineInstrBuilder.h" | |
| #include "llvm/CodeGen/MachineMemOperand.h" | |
| #include "llvm/CodeGen/MachineOperand.h" | |
| #include "llvm/CodeGen/PseudoSourceValue.h" | |
| #include "llvm/CodeGen/TargetFrameLowering.h" | |
| #include "llvm/CodeGen/TargetInstrInfo.h" | |
| #include "llvm/CodeGen/TargetLowering.h" | |
| #include "llvm/CodeGen/TargetRegisterInfo.h" | |
| #include "llvm/CodeGen/TargetSubtargetInfo.h" | |
| #include "llvm/CodeGen/RegisterScavenging.h" | |
| #include "llvm/Config/llvm-config.h" | |
| #include "llvm/IR/DebugInfoMetadata.h" | |
| #include "llvm/IR/DebugLoc.h" | |
| #include "llvm/IR/Function.h" | |
| #include "llvm/IR/Module.h" | |
| #include "llvm/MC/MCRegisterInfo.h" | |
| #include "llvm/Pass.h" | |
| #include "llvm/Support/Casting.h" | |
| #include "llvm/Support/Compiler.h" | |
| #include "llvm/Support/Debug.h" | |
| #include "llvm/Support/raw_ostream.h" | |
| #include <algorithm> | |
| #include <cassert> | |
| #include <cstdint> | |
| #include <functional> | |
| #include <queue> | |
| #include <utility> | |
| #include <vector> | |
| using namespace llvm; | |
| #define DEBUG_TYPE "livedebugvalues" | |
| STATISTIC(NumInserted, "Number of DBG_VALUE instructions inserted"); | |
| // If @MI is a DBG_VALUE with debug value described by a defined | |
| // register, returns the number of this register. In the other case, returns 0. | |
| static unsigned isDbgValueDescribedByReg(const MachineInstr &MI) { | |
| assert(MI.isDebugValue() && "expected a DBG_VALUE"); | |
| assert(MI.getNumOperands() == 4 && "malformed DBG_VALUE"); | |
| // If location of variable is described using a register (directly | |
| // or indirectly), this register is always a first operand. | |
| return MI.getOperand(0).isReg() ? MI.getOperand(0).getReg() : 0; | |
| } | |
| namespace { | |
| class LiveDebugValues : public MachineFunctionPass { | |
| private: | |
| const TargetRegisterInfo *TRI; | |
| const TargetInstrInfo *TII; | |
| const TargetFrameLowering *TFI; | |
| BitVector CalleeSavedRegs; | |
| LexicalScopes LS; | |
| /// Keeps track of lexical scopes associated with a user value's source | |
| /// location. | |
| class UserValueScopes { | |
| DebugLoc DL; | |
| LexicalScopes &LS; | |
| SmallPtrSet<const MachineBasicBlock *, 4> LBlocks; | |
| public: | |
| UserValueScopes(DebugLoc D, LexicalScopes &L) : DL(std::move(D)), LS(L) {} | |
| /// Return true if current scope dominates at least one machine | |
| /// instruction in a given machine basic block. | |
| bool dominates(MachineBasicBlock *MBB) { | |
| if (LBlocks.empty()) | |
| LS.getMachineBasicBlocks(DL, LBlocks); | |
| return LBlocks.count(MBB) != 0 || LS.dominates(DL, MBB); | |
| } | |
| }; | |
| /// Based on std::pair so it can be used as an index into a DenseMap. | |
| using DebugVariableBase = | |
| std::pair<const DILocalVariable *, const DILocation *>; | |
| /// A potentially inlined instance of a variable. | |
| struct DebugVariable : public DebugVariableBase { | |
| DebugVariable(const DILocalVariable *Var, const DILocation *InlinedAt) | |
| : DebugVariableBase(Var, InlinedAt) {} | |
| const DILocalVariable *getVar() const { return this->first; } | |
| const DILocation *getInlinedAt() const { return this->second; } | |
| bool operator<(const DebugVariable &DV) const { | |
| if (getVar() == DV.getVar()) | |
| return getInlinedAt() < DV.getInlinedAt(); | |
| return getVar() < DV.getVar(); | |
| } | |
| }; | |
| /// A pair of debug variable and value location. | |
| struct VarLoc { | |
| const DebugVariable Var; | |
| const MachineInstr &MI; ///< Only used for cloning a new DBG_VALUE. | |
| mutable UserValueScopes UVS; | |
| enum { InvalidKind = 0, RegisterKind } Kind = InvalidKind; | |
| /// The value location. Stored separately to avoid repeatedly | |
| /// extracting it from MI. | |
| union { | |
| uint64_t RegNo; | |
| uint64_t Hash; | |
| } Loc; | |
| VarLoc(const MachineInstr &MI, LexicalScopes &LS) | |
| : Var(MI.getDebugVariable(), MI.getDebugLoc()->getInlinedAt()), MI(MI), | |
| UVS(MI.getDebugLoc(), LS) { | |
| static_assert((sizeof(Loc) == sizeof(uint64_t)), | |
| "hash does not cover all members of Loc"); | |
| assert(MI.isDebugValue() && "not a DBG_VALUE"); | |
| assert(MI.getNumOperands() == 4 && "malformed DBG_VALUE"); | |
| if (int RegNo = isDbgValueDescribedByReg(MI)) { | |
| Kind = RegisterKind; | |
| Loc.RegNo = RegNo; | |
| } | |
| } | |
| /// If this variable is described by a register, return it, | |
| /// otherwise return 0. | |
| unsigned isDescribedByReg() const { | |
| if (Kind == RegisterKind) | |
| return Loc.RegNo; | |
| return 0; | |
| } | |
| /// Determine whether the lexical scope of this value's debug location | |
| /// dominates MBB. | |
| bool dominates(MachineBasicBlock &MBB) const { return UVS.dominates(&MBB); } | |
| #if !defined(NDEBUG) || defined(LLVM_ENABLE_DUMP) | |
| LLVM_DUMP_METHOD void dump() const { MI.dump(); } | |
| #endif | |
| bool operator==(const VarLoc &Other) const { | |
| return Var == Other.Var && Loc.Hash == Other.Loc.Hash; | |
| } | |
| /// This operator guarantees that VarLocs are sorted by Variable first. | |
| bool operator<(const VarLoc &Other) const { | |
| if (Var == Other.Var) | |
| return Loc.Hash < Other.Loc.Hash; | |
| return Var < Other.Var; | |
| } | |
| }; | |
| using VarLocMap = UniqueVector<VarLoc>; | |
| using VarLocSet = SparseBitVector<>; | |
| using VarLocInMBB = SmallDenseMap<const MachineBasicBlock *, VarLocSet>; | |
| struct TransferDebugPair { | |
| MachineInstr *TransferInst; | |
| MachineInstr *DebugInst; | |
| }; | |
| using TransferMap = SmallVector<TransferDebugPair, 4>; | |
| /// This holds the working set of currently open ranges. For fast | |
| /// access, this is done both as a set of VarLocIDs, and a map of | |
| /// DebugVariable to recent VarLocID. Note that a DBG_VALUE ends all | |
| /// previous open ranges for the same variable. | |
| class OpenRangesSet { | |
| VarLocSet VarLocs; | |
| SmallDenseMap<DebugVariableBase, unsigned, 8> Vars; | |
| public: | |
| const VarLocSet &getVarLocs() const { return VarLocs; } | |
| /// Terminate all open ranges for Var by removing it from the set. | |
| void erase(DebugVariable Var) { | |
| auto It = Vars.find(Var); | |
| if (It != Vars.end()) { | |
| unsigned ID = It->second; | |
| VarLocs.reset(ID); | |
| Vars.erase(It); | |
| } | |
| } | |
| /// Terminate all open ranges listed in \c KillSet by removing | |
| /// them from the set. | |
| void erase(const VarLocSet &KillSet, const VarLocMap &VarLocIDs) { | |
| VarLocs.intersectWithComplement(KillSet); | |
| for (unsigned ID : KillSet) | |
| Vars.erase(VarLocIDs[ID].Var); | |
| } | |
| /// Insert a new range into the set. | |
| void insert(unsigned VarLocID, DebugVariableBase Var) { | |
| VarLocs.set(VarLocID); | |
| Vars.insert({Var, VarLocID}); | |
| } | |
| /// Empty the set. | |
| void clear() { | |
| VarLocs.clear(); | |
| Vars.clear(); | |
| } | |
| /// Return whether the set is empty or not. | |
| bool empty() const { | |
| assert(Vars.empty() == VarLocs.empty() && "open ranges are inconsistent"); | |
| return VarLocs.empty(); | |
| } | |
| }; | |
| bool isSpillInstruction(const MachineInstr &MI, MachineFunction *MF, | |
| unsigned &Reg); | |
| int extractSpillBaseRegAndOffset(const MachineInstr &MI, unsigned &Reg); | |
| void insertTransferDebugPair(MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| TransferMap &Transfers, VarLocMap &VarLocIDs, | |
| unsigned OldVarID, unsigned NewReg = 0); | |
| void transferDebugValue(const MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| VarLocMap &VarLocIDs); | |
| void transferSpillInst(MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| VarLocMap &VarLocIDs, TransferMap &Transfers); | |
| void transferRegisterCopy(MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| VarLocMap &VarLocIDs, TransferMap &Transfers); | |
| void transferRegisterDef(MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| const VarLocMap &VarLocIDs); | |
| bool transferTerminatorInst(MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| VarLocInMBB &OutLocs, const VarLocMap &VarLocIDs); | |
| bool process(MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| VarLocInMBB &OutLocs, VarLocMap &VarLocIDs, | |
| TransferMap &Transfers, bool transferChanges); | |
| bool join(MachineBasicBlock &MBB, VarLocInMBB &OutLocs, VarLocInMBB &InLocs, | |
| const VarLocMap &VarLocIDs, | |
| SmallPtrSet<const MachineBasicBlock *, 16> &Visited); | |
| bool ExtendRanges(MachineFunction &MF); | |
| public: | |
| static char ID; | |
| /// Default construct and initialize the pass. | |
| LiveDebugValues(); | |
| /// Tell the pass manager which passes we depend on and what | |
| /// information we preserve. | |
| void getAnalysisUsage(AnalysisUsage &AU) const override; | |
| MachineFunctionProperties getRequiredProperties() const override { | |
| return MachineFunctionProperties().set( | |
| MachineFunctionProperties::Property::NoVRegs); | |
| } | |
| /// Print to ostream with a message. | |
| void printVarLocInMBB(const MachineFunction &MF, const VarLocInMBB &V, | |
| const VarLocMap &VarLocIDs, const char *msg, | |
| raw_ostream &Out) const; | |
| /// Calculate the liveness information for the given machine function. | |
| bool runOnMachineFunction(MachineFunction &MF) override; | |
| }; | |
| } // end anonymous namespace | |
| //===----------------------------------------------------------------------===// | |
| // Implementation | |
| //===----------------------------------------------------------------------===// | |
| char LiveDebugValues::ID = 0; | |
| char &llvm::LiveDebugValuesID = LiveDebugValues::ID; | |
| INITIALIZE_PASS(LiveDebugValues, DEBUG_TYPE, "Live DEBUG_VALUE analysis", | |
| false, false) | |
| /// Default construct and initialize the pass. | |
| LiveDebugValues::LiveDebugValues() : MachineFunctionPass(ID) { | |
| initializeLiveDebugValuesPass(*PassRegistry::getPassRegistry()); | |
| } | |
| /// Tell the pass manager which passes we depend on and what information we | |
| /// preserve. | |
| void LiveDebugValues::getAnalysisUsage(AnalysisUsage &AU) const { | |
| AU.setPreservesCFG(); | |
| MachineFunctionPass::getAnalysisUsage(AU); | |
| } | |
| //===----------------------------------------------------------------------===// | |
| // Debug Range Extension Implementation | |
| //===----------------------------------------------------------------------===// | |
| #ifndef NDEBUG | |
| void LiveDebugValues::printVarLocInMBB(const MachineFunction &MF, | |
| const VarLocInMBB &V, | |
| const VarLocMap &VarLocIDs, | |
| const char *msg, | |
| raw_ostream &Out) const { | |
| Out << '\n' << msg << '\n'; | |
| for (const MachineBasicBlock &BB : MF) { | |
| const auto &L = V.lookup(&BB); | |
| Out << "MBB: " << BB.getName() << ":\n"; | |
| for (unsigned VLL : L) { | |
| const VarLoc &VL = VarLocIDs[VLL]; | |
| Out << " Var: " << VL.Var.getVar()->getName(); | |
| Out << " MI: "; | |
| VL.dump(); | |
| } | |
| } | |
| Out << "\n"; | |
| } | |
| #endif | |
| /// Given a spill instruction, extract the register and offset used to | |
| /// address the spill location in a target independent way. | |
| int LiveDebugValues::extractSpillBaseRegAndOffset(const MachineInstr &MI, | |
| unsigned &Reg) { | |
| assert(MI.hasOneMemOperand() && | |
| "Spill instruction does not have exactly one memory operand?"); | |
| auto MMOI = MI.memoperands_begin(); | |
| const PseudoSourceValue *PVal = (*MMOI)->getPseudoValue(); | |
| assert(PVal->kind() == PseudoSourceValue::FixedStack && | |
| "Inconsistent memory operand in spill instruction"); | |
| int FI = cast<FixedStackPseudoSourceValue>(PVal)->getFrameIndex(); | |
| const MachineBasicBlock *MBB = MI.getParent(); | |
| return TFI->getFrameIndexReference(*MBB->getParent(), FI, Reg); | |
| } | |
| /// End all previous ranges related to @MI and start a new range from @MI | |
| /// if it is a DBG_VALUE instr. | |
| void LiveDebugValues::transferDebugValue(const MachineInstr &MI, | |
| OpenRangesSet &OpenRanges, | |
| VarLocMap &VarLocIDs) { | |
| if (!MI.isDebugValue()) | |
| return; | |
| const DILocalVariable *Var = MI.getDebugVariable(); | |
| const DILocation *DebugLoc = MI.getDebugLoc(); | |
| const DILocation *InlinedAt = DebugLoc->getInlinedAt(); | |
| assert(Var->isValidLocationForIntrinsic(DebugLoc) && | |
| "Expected inlined-at fields to agree"); | |
| // End all previous ranges of Var. | |
| DebugVariable V(Var, InlinedAt); | |
| OpenRanges.erase(V); | |
| // Add the VarLoc to OpenRanges from this DBG_VALUE. | |
| // TODO: Currently handles DBG_VALUE which has only reg as location. | |
| if (isDbgValueDescribedByReg(MI)) { | |
| VarLoc VL(MI, LS); | |
| unsigned ID = VarLocIDs.insert(VL); | |
| OpenRanges.insert(ID, VL.Var); | |
| } | |
| } | |
| /// Create new TransferDebugPair and insert it in \p Transfers. The VarLoc | |
| /// with \p OldVarID should be deleted form \p OpenRanges and replaced with | |
| /// new VarLoc. If \p NewReg is different than default zero value then the | |
| /// new location will be register location created by the copy like instruction, | |
| /// otherwise it is variable's location on the stack. | |
| void LiveDebugValues::insertTransferDebugPair( | |
| MachineInstr &MI, OpenRangesSet &OpenRanges, TransferMap &Transfers, | |
| VarLocMap &VarLocIDs, unsigned OldVarID, unsigned NewReg) { | |
| const MachineInstr *DMI = &VarLocIDs[OldVarID].MI; | |
| MachineFunction *MF = MI.getParent()->getParent(); | |
| MachineInstr *NewDMI; | |
| if (NewReg) { | |
| // Create a DBG_VALUE instruction to describe the Var in its new | |
| // register location. | |
| NewDMI = BuildMI(*MF, DMI->getDebugLoc(), DMI->getDesc(), | |
| DMI->isIndirectDebugValue(), NewReg, | |
| DMI->getDebugVariable(), DMI->getDebugExpression()); | |
| if (DMI->isIndirectDebugValue()) | |
| NewDMI->getOperand(1).setImm(DMI->getOperand(1).getImm()); | |
| LLVM_DEBUG(dbgs() << "Creating DBG_VALUE inst for register copy: "; | |
| NewDMI->print(dbgs(), false, false, false, TII)); | |
| } else { | |
| // Create a DBG_VALUE instruction to describe the Var in its spilled | |
| // location. | |
| unsigned SpillBase; | |
| int SpillOffset = extractSpillBaseRegAndOffset(MI, SpillBase); | |
| auto *SpillExpr = DIExpression::prepend(DMI->getDebugExpression(), | |
| DIExpression::NoDeref, SpillOffset); | |
| NewDMI = BuildMI(*MF, DMI->getDebugLoc(), DMI->getDesc(), true, SpillBase, | |
| DMI->getDebugVariable(), SpillExpr); | |
| LLVM_DEBUG(dbgs() << "Creating DBG_VALUE inst for spill: "; | |
| NewDMI->print(dbgs(), false, false, false, TII)); | |
| } | |
| // The newly created DBG_VALUE instruction NewDMI must be inserted after | |
| // MI. Keep track of the pairing. | |
| TransferDebugPair MIP = {&MI, NewDMI}; | |
| Transfers.push_back(MIP); | |
| // End all previous ranges of Var. | |
| OpenRanges.erase(VarLocIDs[OldVarID].Var); | |
| // Add the VarLoc to OpenRanges. | |
| VarLoc VL(*NewDMI, LS); | |
| unsigned LocID = VarLocIDs.insert(VL); | |
| OpenRanges.insert(LocID, VL.Var); | |
| } | |
| /// A definition of a register may mark the end of a range. | |
| void LiveDebugValues::transferRegisterDef(MachineInstr &MI, | |
| OpenRangesSet &OpenRanges, | |
| const VarLocMap &VarLocIDs) { | |
| MachineFunction *MF = MI.getMF(); | |
| const TargetLowering *TLI = MF->getSubtarget().getTargetLowering(); | |
| unsigned SP = TLI->getStackPointerRegisterToSaveRestore(); | |
| SparseBitVector<> KillSet; | |
| for (const MachineOperand &MO : MI.operands()) { | |
| // Determine whether the operand is a register def. Assume that call | |
| // instructions never clobber SP, because some backends (e.g., AArch64) | |
| // never list SP in the regmask. | |
| if (MO.isReg() && MO.isDef() && MO.getReg() && | |
| TRI->isPhysicalRegister(MO.getReg()) && | |
| !(MI.isCall() && MO.getReg() == SP)) { | |
| // Remove ranges of all aliased registers. | |
| for (MCRegAliasIterator RAI(MO.getReg(), TRI, true); RAI.isValid(); ++RAI) | |
| for (unsigned ID : OpenRanges.getVarLocs()) | |
| if (VarLocIDs[ID].isDescribedByReg() == *RAI) | |
| KillSet.set(ID); | |
| } else if (MO.isRegMask()) { | |
| // Remove ranges of all clobbered registers. Register masks don't usually | |
| // list SP as preserved. While the debug info may be off for an | |
| // instruction or two around callee-cleanup calls, transferring the | |
| // DEBUG_VALUE across the call is still a better user experience. | |
| for (unsigned ID : OpenRanges.getVarLocs()) { | |
| unsigned Reg = VarLocIDs[ID].isDescribedByReg(); | |
| if (Reg && Reg != SP && MO.clobbersPhysReg(Reg)) | |
| KillSet.set(ID); | |
| } | |
| } | |
| } | |
| OpenRanges.erase(KillSet, VarLocIDs); | |
| } | |
| /// Decide if @MI is a spill instruction and return true if it is. We use 2 | |
| /// criteria to make this decision: | |
| /// - Is this instruction a store to a spill slot? | |
| /// - Is there a register operand that is both used and killed? | |
| /// TODO: Store optimization can fold spills into other stores (including | |
| /// other spills). We do not handle this yet (more than one memory operand). | |
| bool LiveDebugValues::isSpillInstruction(const MachineInstr &MI, | |
| MachineFunction *MF, unsigned &Reg) { | |
| const MachineFrameInfo &FrameInfo = MF->getFrameInfo(); | |
| int FI; | |
| const MachineMemOperand *MMO; | |
| // TODO: Handle multiple stores folded into one. | |
| if (!MI.hasOneMemOperand()) | |
| return false; | |
| // To identify a spill instruction, use the same criteria as in AsmPrinter. | |
| if (!((TII->isStoreToStackSlotPostFE(MI, FI) || | |
| TII->hasStoreToStackSlot(MI, MMO, FI)) && | |
| FrameInfo.isSpillSlotObjectIndex(FI))) | |
| return false; | |
| auto isKilledReg = [&](const MachineOperand MO, unsigned &Reg) { | |
| if (!MO.isReg() || !MO.isUse()) { | |
| Reg = 0; | |
| return false; | |
| } | |
| Reg = MO.getReg(); | |
| return MO.isKill(); | |
| }; | |
| for (const MachineOperand &MO : MI.operands()) { | |
| // In a spill instruction generated by the InlineSpiller the spilled | |
| // register has its kill flag set. | |
| if (isKilledReg(MO, Reg)) | |
| return true; | |
| if (Reg != 0) { | |
| // Check whether next instruction kills the spilled register. | |
| // FIXME: Current solution does not cover search for killed register in | |
| // bundles and instructions further down the chain. | |
| auto NextI = std::next(MI.getIterator()); | |
| // Skip next instruction that points to basic block end iterator. | |
| if (MI.getParent()->end() == NextI) | |
| continue; | |
| unsigned RegNext; | |
| for (const MachineOperand &MONext : NextI->operands()) { | |
| // Return true if we came across the register from the | |
| // previous spill instruction that is killed in NextI. | |
| if (isKilledReg(MONext, RegNext) && RegNext == Reg) | |
| return true; | |
| } | |
| } | |
| } | |
| // Return false if we didn't find spilled register. | |
| return false; | |
| } | |
| /// A spilled register may indicate that we have to end the current range of | |
| /// a variable and create a new one for the spill location. | |
| /// We don't want to insert any instructions in process(), so we just create | |
| /// the DBG_VALUE without inserting it and keep track of it in \p Transfers. | |
| /// It will be inserted into the BB when we're done iterating over the | |
| /// instructions. | |
| void LiveDebugValues::transferSpillInst(MachineInstr &MI, | |
| OpenRangesSet &OpenRanges, | |
| VarLocMap &VarLocIDs, | |
| TransferMap &Transfers) { | |
| unsigned Reg; | |
| MachineFunction *MF = MI.getMF(); | |
| if (!isSpillInstruction(MI, MF, Reg)) | |
| return; | |
| // Check if the register is the location of a debug value. | |
| for (unsigned ID : OpenRanges.getVarLocs()) { | |
| if (VarLocIDs[ID].isDescribedByReg() == Reg) { | |
| LLVM_DEBUG(dbgs() << "Spilling Register " << printReg(Reg, TRI) << '(' | |
| << VarLocIDs[ID].Var.getVar()->getName() << ")\n"); | |
| insertTransferDebugPair(MI, OpenRanges, Transfers, VarLocIDs, ID); | |
| return; | |
| } | |
| } | |
| } | |
| /// If \p MI is a register copy instruction, that copies a previously tracked | |
| /// value from one register to another register that is callee saved, we | |
| /// create new DBG_VALUE instruction described with copy destination register. | |
| void LiveDebugValues::transferRegisterCopy(MachineInstr &MI, | |
| OpenRangesSet &OpenRanges, | |
| VarLocMap &VarLocIDs, | |
| TransferMap &Transfers) { | |
| const MachineOperand *SrcRegOp, *DestRegOp; | |
| if (!TII->isCopyInstr(MI, SrcRegOp, DestRegOp) || !SrcRegOp->isKill() || | |
| !DestRegOp->isDef()) | |
| return; | |
| auto isCalleSavedReg = [&](unsigned Reg) { | |
| for (MCRegAliasIterator RAI(Reg, TRI, true); RAI.isValid(); ++RAI) | |
| if (CalleeSavedRegs.test(*RAI)) | |
| return true; | |
| return false; | |
| }; | |
| unsigned SrcReg = SrcRegOp->getReg(); | |
| unsigned DestReg = DestRegOp->getReg(); | |
| // We want to recognize instructions where destination register is callee | |
| // saved register. If register that could be clobbered by the call is | |
| // included, there would be a great chance that it is going to be clobbered | |
| // soon. It is more likely that previous register location, which is callee | |
| // saved, is going to stay unclobbered longer, even if it is killed. | |
| if (!isCalleSavedReg(DestReg)) | |
| return; | |
| for (unsigned ID : OpenRanges.getVarLocs()) { | |
| if (VarLocIDs[ID].isDescribedByReg() == SrcReg) { | |
| insertTransferDebugPair(MI, OpenRanges, Transfers, VarLocIDs, ID, | |
| DestReg); | |
| return; | |
| } | |
| } | |
| } | |
| /// Terminate all open ranges at the end of the current basic block. | |
| bool LiveDebugValues::transferTerminatorInst(MachineInstr &MI, | |
| OpenRangesSet &OpenRanges, | |
| VarLocInMBB &OutLocs, | |
| const VarLocMap &VarLocIDs) { | |
| bool Changed = false; | |
| const MachineBasicBlock *CurMBB = MI.getParent(); | |
| if (!(MI.isTerminator() || (&MI == &CurMBB->back()))) | |
| return false; | |
| if (OpenRanges.empty()) | |
| return false; | |
| LLVM_DEBUG(for (unsigned ID | |
| : OpenRanges.getVarLocs()) { | |
| // Copy OpenRanges to OutLocs, if not already present. | |
| dbgs() << "Add to OutLocs: "; | |
| VarLocIDs[ID].dump(); | |
| }); | |
| VarLocSet &VLS = OutLocs[CurMBB]; | |
| Changed = VLS |= OpenRanges.getVarLocs(); | |
| OpenRanges.clear(); | |
| return Changed; | |
| } | |
| /// This routine creates OpenRanges and OutLocs. | |
| bool LiveDebugValues::process(MachineInstr &MI, OpenRangesSet &OpenRanges, | |
| VarLocInMBB &OutLocs, VarLocMap &VarLocIDs, | |
| TransferMap &Transfers, bool transferChanges) { | |
| bool Changed = false; | |
| transferDebugValue(MI, OpenRanges, VarLocIDs); | |
| transferRegisterDef(MI, OpenRanges, VarLocIDs); | |
| if (transferChanges) { | |
| transferRegisterCopy(MI, OpenRanges, VarLocIDs, Transfers); | |
| transferSpillInst(MI, OpenRanges, VarLocIDs, Transfers); | |
| } | |
| Changed = transferTerminatorInst(MI, OpenRanges, OutLocs, VarLocIDs); | |
| return Changed; | |
| } | |
| /// This routine joins the analysis results of all incoming edges in @MBB by | |
| /// inserting a new DBG_VALUE instruction at the start of the @MBB - if the same | |
| /// source variable in all the predecessors of @MBB reside in the same location. | |
| bool LiveDebugValues::join(MachineBasicBlock &MBB, VarLocInMBB &OutLocs, | |
| VarLocInMBB &InLocs, const VarLocMap &VarLocIDs, | |
| SmallPtrSet<const MachineBasicBlock *, 16> &Visited) { | |
| LLVM_DEBUG(dbgs() << "join MBB: " << MBB.getName() << "\n"); | |
| bool Changed = false; | |
| VarLocSet InLocsT; // Temporary incoming locations. | |
| // For all predecessors of this MBB, find the set of VarLocs that | |
| // can be joined. | |
| int NumVisited = 0; | |
| for (auto p : MBB.predecessors()) { | |
| // Ignore unvisited predecessor blocks. As we are processing | |
| // the blocks in reverse post-order any unvisited block can | |
| // be considered to not remove any incoming values. | |
| if (!Visited.count(p)) | |
| continue; | |
| auto OL = OutLocs.find(p); | |
| // Join is null in case of empty OutLocs from any of the pred. | |
| if (OL == OutLocs.end()) | |
| return false; | |
| // Just copy over the Out locs to incoming locs for the first visited | |
| // predecessor, and for all other predecessors join the Out locs. | |
| if (!NumVisited) | |
| InLocsT = OL->second; | |
| else | |
| InLocsT &= OL->second; | |
| NumVisited++; | |
| } | |
| // Filter out DBG_VALUES that are out of scope. | |
| VarLocSet KillSet; | |
| for (auto ID : InLocsT) | |
| if (!VarLocIDs[ID].dominates(MBB)) | |
| KillSet.set(ID); | |
| InLocsT.intersectWithComplement(KillSet); | |
| // As we are processing blocks in reverse post-order we | |
| // should have processed at least one predecessor, unless it | |
| // is the entry block which has no predecessor. | |
| assert((NumVisited || MBB.pred_empty()) && | |
| "Should have processed at least one predecessor"); | |
| if (InLocsT.empty()) | |
| return false; | |
| VarLocSet &ILS = InLocs[&MBB]; | |
| // Insert DBG_VALUE instructions, if not already inserted. | |
| VarLocSet Diff = InLocsT; | |
| Diff.intersectWithComplement(ILS); | |
| for (auto ID : Diff) { | |
| // This VarLoc is not found in InLocs i.e. it is not yet inserted. So, a | |
| // new range is started for the var from the mbb's beginning by inserting | |
| // a new DBG_VALUE. process() will end this range however appropriate. | |
| const VarLoc &DiffIt = VarLocIDs[ID]; | |
| const MachineInstr *DMI = &DiffIt.MI; | |
| MachineInstr *MI = | |
| BuildMI(MBB, MBB.instr_begin(), DMI->getDebugLoc(), DMI->getDesc(), | |
| DMI->isIndirectDebugValue(), DMI->getOperand(0).getReg(), | |
| DMI->getDebugVariable(), DMI->getDebugExpression()); | |
| if (DMI->isIndirectDebugValue()) | |
| MI->getOperand(1).setImm(DMI->getOperand(1).getImm()); | |
| LLVM_DEBUG(dbgs() << "Inserted: "; MI->dump();); | |
| ILS.set(ID); | |
| ++NumInserted; | |
| Changed = true; | |
| } | |
| return Changed; | |
| } | |
| /// Calculate the liveness information for the given machine function and | |
| /// extend ranges across basic blocks. | |
| bool LiveDebugValues::ExtendRanges(MachineFunction &MF) { | |
| LLVM_DEBUG(dbgs() << "\nDebug Range Extension\n"); | |
| bool Changed = false; | |
| bool OLChanged = false; | |
| bool MBBJoined = false; | |
| VarLocMap VarLocIDs; // Map VarLoc<>unique ID for use in bitvectors. | |
| OpenRangesSet OpenRanges; // Ranges that are open until end of bb. | |
| VarLocInMBB OutLocs; // Ranges that exist beyond bb. | |
| VarLocInMBB InLocs; // Ranges that are incoming after joining. | |
| TransferMap Transfers; // DBG_VALUEs associated with spills. | |
| DenseMap<unsigned int, MachineBasicBlock *> OrderToBB; | |
| DenseMap<MachineBasicBlock *, unsigned int> BBToOrder; | |
| std::priority_queue<unsigned int, std::vector<unsigned int>, | |
| std::greater<unsigned int>> | |
| Worklist; | |
| std::priority_queue<unsigned int, std::vector<unsigned int>, | |
| std::greater<unsigned int>> | |
| Pending; | |
| enum : bool { dontTransferChanges = false, transferChanges = true }; | |
| // Initialize every mbb with OutLocs. | |
| // We are not looking at any spill instructions during the initial pass | |
| // over the BBs. The LiveDebugVariables pass has already created DBG_VALUE | |
| // instructions for spills of registers that are known to be user variables | |
| // within the BB in which the spill occurs. | |
| for (auto &MBB : MF) | |
| for (auto &MI : MBB) | |
| process(MI, OpenRanges, OutLocs, VarLocIDs, Transfers, | |
| dontTransferChanges); | |
| LLVM_DEBUG(printVarLocInMBB(MF, OutLocs, VarLocIDs, | |
| "OutLocs after initialization", dbgs())); | |
| ReversePostOrderTraversal<MachineFunction *> RPOT(&MF); | |
| unsigned int RPONumber = 0; | |
| for (auto RI = RPOT.begin(), RE = RPOT.end(); RI != RE; ++RI) { | |
| OrderToBB[RPONumber] = *RI; | |
| BBToOrder[*RI] = RPONumber; | |
| Worklist.push(RPONumber); | |
| ++RPONumber; | |
| } | |
| // This is a standard "union of predecessor outs" dataflow problem. | |
| // To solve it, we perform join() and process() using the two worklist method | |
| // until the ranges converge. | |
| // Ranges have converged when both worklists are empty. | |
| SmallPtrSet<const MachineBasicBlock *, 16> Visited; | |
| while (!Worklist.empty() || !Pending.empty()) { | |
| // We track what is on the pending worklist to avoid inserting the same | |
| // thing twice. We could avoid this with a custom priority queue, but this | |
| // is probably not worth it. | |
| SmallPtrSet<MachineBasicBlock *, 16> OnPending; | |
| LLVM_DEBUG(dbgs() << "Processing Worklist\n"); | |
| while (!Worklist.empty()) { | |
| MachineBasicBlock *MBB = OrderToBB[Worklist.top()]; | |
| Worklist.pop(); | |
| MBBJoined = join(*MBB, OutLocs, InLocs, VarLocIDs, Visited); | |
| Visited.insert(MBB); | |
| if (MBBJoined) { | |
| MBBJoined = false; | |
| Changed = true; | |
| // Now that we have started to extend ranges across BBs we need to | |
| // examine spill instructions to see whether they spill registers that | |
| // correspond to user variables. | |
| for (auto &MI : *MBB) | |
| OLChanged |= process(MI, OpenRanges, OutLocs, VarLocIDs, Transfers, | |
| transferChanges); | |
| // Add any DBG_VALUE instructions necessitated by spills. | |
| for (auto &TR : Transfers) | |
| MBB->insertAfter(MachineBasicBlock::iterator(*TR.TransferInst), | |
| TR.DebugInst); | |
| Transfers.clear(); | |
| LLVM_DEBUG(printVarLocInMBB(MF, OutLocs, VarLocIDs, | |
| "OutLocs after propagating", dbgs())); | |
| LLVM_DEBUG(printVarLocInMBB(MF, InLocs, VarLocIDs, | |
| "InLocs after propagating", dbgs())); | |
| if (OLChanged) { | |
| OLChanged = false; | |
| for (auto s : MBB->successors()) | |
| if (OnPending.insert(s).second) { | |
| Pending.push(BBToOrder[s]); | |
| } | |
| } | |
| } | |
| } | |
| Worklist.swap(Pending); | |
| // At this point, pending must be empty, since it was just the empty | |
| // worklist | |
| assert(Pending.empty() && "Pending should be empty"); | |
| } | |
| LLVM_DEBUG(printVarLocInMBB(MF, OutLocs, VarLocIDs, "Final OutLocs", dbgs())); | |
| LLVM_DEBUG(printVarLocInMBB(MF, InLocs, VarLocIDs, "Final InLocs", dbgs())); | |
| return Changed; | |
| } | |
| bool LiveDebugValues::runOnMachineFunction(MachineFunction &MF) { | |
| if (!MF.getFunction().getSubprogram()) | |
| // LiveDebugValues will already have removed all DBG_VALUEs. | |
| return false; | |
| // Skip functions from NoDebug compilation units. | |
| if (MF.getFunction().getSubprogram()->getUnit()->getEmissionKind() == | |
| DICompileUnit::NoDebug) | |
| return false; | |
| TRI = MF.getSubtarget().getRegisterInfo(); | |
| TII = MF.getSubtarget().getInstrInfo(); | |
| TFI = MF.getSubtarget().getFrameLowering(); | |
| TFI->determineCalleeSaves(MF, CalleeSavedRegs, | |
| make_unique<RegScavenger>().get()); | |
| LS.initialize(MF); | |
| bool Changed = ExtendRanges(MF); | |
| return Changed; | |
| } |